EasyManua.ls Logo

SPM Machine Guard MG4-REF11A - SPM Transducer 42000; SPM 42000 Transducer Features and Installation

SPM Machine Guard MG4-REF11A
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden
Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com
ISO 9001:2000 certified © SPM 2017-09. 71947 B
27
SPM transducer 42000
The shock pulse transducer with built-in matching
unit is used in permanent installations. It converts
the shock pulses into an electric signal, and stabi-
lizes the signal for transmission via a long cable.
A coaxial cable, length max. 100 m, connects the
transducer with a measuring device. The trans-
ducer is installed in a countersunk mounting hole
on the machine, as close as possible to the shock
sources. Thread size is M8, with UNC 5/16” as an
alternative.
Transducer housing and base are made of stain-
less, acid proof steel, suitable for aggressive
environments.
The transducer is normally connected via a meas-
uring cable, 45011-L, with TNC crimp connectors.
SPM 45011-L
Mounting hole
min. 15 mm
Space
min. 115 mm
Technical data
Measuring range: Max. 100 dBsv
Housing, base: Stainless acid proof
steel, Sandvik Grade:
1802, EN:1.4523
Design: Sealed
Temperature range: –30 to +100 °C
External overpressure: Max. 0.7 MPa (7 bar)
Torque: 15 Nm, max. 20 Nm
Connector: TNC jack
Shock pulse transducer 42000
Ordering numbers
42000 Shock pulse transducer with TMU,
M8
42100 Shock pulse transducer with TMU,
UNC 5/16”
M8 /
UNC 5/16”