So Alarms: The following remaining errors give a 15 second audible chirp only
System Display Problem Resoluon
The module indicated is
no longer communicat-
ing to with the system.
Ensure all modules are
connected properly to the
system and to each other.
Modules can be tested
individually by plugging in
one at a me and cycling
power to the system.
Replace any module that is
not detected when plugged
directly into the controller.
Refer to ow meter manual for detailed
troubleshoong
Warning: Aer any hard alarm, the home or facility should be disinfected. Follow the steps
under the “System Disinfecon” heading.
Temperature Management Devices
Your UV system is designed to run connuously to ensure opmal disinfecon. However, during
periods when no water is drawn through the system, the energy from the disinfecon process
can cause the temperature of the water inside the chamber to rise. In extreme situaons
elevated water temperature or the uctuaon in temperature can lower the output of the UV
lamp. In these cases, or if the elevated water temperature is a nuisance, SpringWell recommends
one of the following forms of temperature management devices.
Cooling Fan - Designed for use on High Output systems, the fan runs connuously to
cool the water by forced convecon. The long-life fan is powered independently
using a compact modular power adapter that operates from 90-265V (47-63Hz).
Order PN SPRW-130014.
Temperature Relief Valve (TRV) - On reaching a higher temperature, the TRV is
designed to drain a small amount of water to allow fresh, cooler water to enter the
system. The TRV works without power and comes complete with 10’ of drain line.
Order PN SPRW-UV-TRV05 for 1/2” ports, PN SPRW-UV-TRV07 for 3/4” ports, PN
SPRW-UV-TRV10 for 1” ports and PN SPRW-UV-TRV15 for 1 1/2” ports.
Boil Water Advisory: If any failure occurs on a UV system, the water must not be used for
human consumpon unl the system is returned to a safe operaonal mode. If the water
is used for human consumpon during this period, the water must be boiled (minimum 20
minutes at a full boil) prior to consumpon.