HHE, HHL, HHS SERIES
Pressure-Swing Desiccant Type Compressed Air Dryers with AccuShift™ Switching Valves
FORM NO.: 3162258 REVISION: 03/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT.
INSTRUCTION MANUAL
MODELS
RATED
FLOW
REFER
AS
MODELS
HHE
SERIES
w/ Timer
Controller
HHL
SERIES
w/ Level 1
Controller
HHS
SERIES
w/ Level 2
Controller
HHE-40
HHE-60
HHE-90
HHL-40
HHL-60
HHL-90
HHS-40
HHS-60
HHS-90
40 SCFM
60 SCFM
90 SCFM
40
60
90
HHE-115
HHE-165
HHE-260
HHL-115
HHL-165
HHL-260
HHS-115
HHS-165
HHS-260
115 SCFM
165 SCFM
260 SCFM
115
165
260
HHE-370
HHE-450
HHE-590
HHL-370
HHL-450
HHL-590
HHS-370
HHS-450
HHS-590
370 SCFM
450 SCFM
590 SCFM
370
450
590
HHE-750
HHE-930
HHE-1130
HHL-750
HHL-930
HHL-1130
HHS-750
HHS-930
HHS-1130
750 SCFM
930 SCFM
1130 SCFM
750
930
1130
HHE-1350
HHE-1550
HHE-2100
HHL-1350
HHL-1550
HHL-2100
HHS-1350
HHS-1550
HHS-2100
1350 SCFM
1550 SCFM
2100 SCFM
1350
1550
2100
HHE-3000
HHE-4100
HHE-5400
HHL-3000
HHL-4100
HHL-5400
HHS-3000
HHS-4100
HHS-5400
3000 SCFM
4100 SCFM
5400 SCFM
3000
4100
5400
Question and Answer IconNeed help?

Do you have a question about the SPX Hankinson HHS-1550 and is the answer not in the manual?

SPX Hankinson HHS-1550 Specifications

General IconGeneral
ModelHHS-1550
Nominal Capacity1550 SCFM
Inlet Temperature100°F
Pressure Dew Point-40 °F
TypeHeatless Regenerative

Summary

General Safety Information

Pressurized Devices Safety

Precautions for pressure-containing equipment.

Electrical Safety Precautions

Guidelines for safe electrical operation and servicing.

Breathing Air Quality

Information on air suitability for breathing and relevant standards.

Desiccant Dryer Description and Operation

Dryer Functionality and APSS

Explains dryer operation and the Automatic Purge Saving System.

Installation Guidelines

System Location and Air Quality

Recommendations for optimal dryer placement and inlet air conditions.

Operating Conditions and Pressure

Information on minimum/maximum operating pressures and temperatures.

Controller General Information

Controller Overview

Introduction to dryer controller levels and features.

Level 1 Controller Operation

Level 2 Controller Operation and APSS

Dryer Operation Procedures

Start-up Procedures

Steps for initial dryer start-up, including controller settings.

Pressurization, Energizing, and Purge Rate

Procedures for pressurizing, energizing, and setting purge pressure.

Operational Check Points

Regular checks for power, moisture indicator, pressure, and alarms.

Operating Parameters Verification

Checking if the dryer operates within specified parameters.

Dryer Maintenance Procedures

Desiccant Replacement

Instructions and frequency for replacing desiccant material.

Troubleshooting Dryer Symptoms

Desiccant Saturation and Tower Repressurization

Identifying causes for premature desiccant saturation and tower repressurization problems.

Related product manuals