Defines signal words DANGER, WARNING, CAUTION and emphasizes reading safety instructions.
Information regarding the dryer's data plate and how to obtain a replacement if missing or damaged.
Procedure for inspecting the dryer upon receipt, documenting damages, and handling claims with the carrier.
Specifies the recommended indoor ambient air temperature range for optimal dryer operation and avoiding issues.
Guidelines for selecting a dryer location and ensuring adequate clearance for cooling and service access.
Recommendations for dryer placement relative to aftercoolers, separators, and receiver tanks for performance.
Requirements for piping material, pressure rating, support, and connection sizes according to codes.
Instructions for draining condensate, including pipe size and connection to a disposal system.
Field wiring must comply with codes. Verify line voltage matches dryer data plate for safe operation.
Description of how air passes through the heat exchangers and refrigeration chiller for moisture removal.
Overview of the refrigeration system components, including compressor, controls, and automatic expansion valve.
Explanation of the color indicator's function and what red or green zones signify during operation.
Refrigeration system maintenance should be done by a qualified mechanic. Contact distributor for warranty work.
Check the operation of the electronic drain valve at least once per 8-hour shift.
Inspect condenser coils for dirt or particles and clean if necessary for optimal performance.
Instructions for returning the dryer or components, including obtaining authorization and shipping details.
Identifies common problems, causes, and remedies for water downstream, pressure drop, and drain valve issues.
Electrical schematic diagram for HX76K and HX101K models, detailing component connections and layout.
Electrical schematic diagram for the HX151K model, illustrating component connections and wiring.
Electrical schematic for HX201K to HX500K models, showing component layout and electrical connections.
Electrical schematic for the HX601K model, detailing the electrical connections and component arrangement.
The JEMACO HXK Series Refrigerated Air Dryers, an SPX brand, are designed to remove moisture from compressed air through mechanical refrigeration. This manual covers models HX76K through HX601K, providing essential information for installation, operation, and maintenance.
These dryers utilize a refrigeration cooling process to condense entrained moisture from the air stream. Warm, saturated air first enters an air-to-air heat exchanger where it is pre-cooled by outgoing cold, dry air. This pre-cooling step condenses up to 65% of the moisture before the air reaches the refrigeration chiller, reducing the heat load on the refrigerant compressor and allowing for a smaller compressor. After passing through the chiller, the cold, dry air is reheated by the incoming warm air in the air-to-air heat exchanger. The refrigeration system is designed and fabricated according to recognized commercial/industrial practices, incorporating a compressor, controls, safety interlocks, and associated equipment for safe performance. All models use a constant pressure expansion valve that automatically modulates refrigerant flow in response to pressure changes, adjusted at the factory for fully automatic operation.
The dryers are rated for specific capacities, power supplies, and input power, as detailed in Table 4 of the manual. For instance, the HX76K model has a rated capacity of 2.50 Nm³/min, a 230V/1/50Hz power supply, 0.58 kW input power, and uses R134a refrigerant. Larger models like the HX601K have a capacity of 18.02 Nm³/min, a 380~420V/3/50Hz power supply, 3.40 kW input power, and use R-407C refrigerant.
Dimensions vary by model, with heights ranging from 601mm to 811mm, widths from 363mm to 543mm, and depths from 861mm to 1321mm (Table 3). Inlet and outlet connections are typically 1 inch for smaller models and up to 2 1/2 inches for larger ones.
Operating conditions (Table 5) specify a maximum inlet air pressure of 16 barg and a minimum of 3 barg. Maximum inlet air temperature is 49°C, with a minimum of 4°C. Ambient air temperatures should range between 4°C and 43°C. Continuous operation outside these maximum and minimum conditions is not allowable.
Refrigerant pressure switch settings (Table 2) are crucial for proper operation. For HX76K~101K models, the fan pressure switch turns on at 12 ± 1 bar and off at 7 ± 1 bar. For HX151K~601K, these settings are 21 ± 1 bar (on) and 15 ± 1 bar (off). The high-pressure switch for HX76K~101K models cuts out at 21 ± 1 bar and requires a manual reset. Suction pressure values (Table 1) are provided for both without airflow and with airflow conditions, varying by refrigerant type (R-134a or R-407C).