Questions and Answers

  • C
    Charlene GuerreroAug 13, 2025
    Why my SPX Power Team PE18 electric motor does not run?
    • J
      Jesse OlsonAug 13, 2025
      If the SPX Water Pump's electric motor isn't running, make sure the switch is in the RUN position and that the unit is properly plugged in. Check the line voltage and the reset button on the power panel. If these steps don't solve the issue, the brushes may be worn and need replacement. Also, the circuit breaker might have tripped due to high amperage; try an alternative circuit or consult an electrician for an additional one. The motor could be overheated (for single-phase motors) or the magnetic starter disengaged (for three-phase motors); let the motor cool and reset the thermal protector. If the thermal protector or magnetic starter is faulty, replace them.
  • J
    Jared TrevinoAug 17, 2025
    What to do if SPX Water Pump is not delivering fluid?
    • S
      Sherry RobinsonAug 17, 2025
      If your SPX Water Pump isn't delivering fluid properly, start by checking the fluid level and adding more if it's low. Ensure the quick-disconnect couplings to cylinders are fully connected and replace them if worn. Bleed air from the system. Inspect the suction line for air leaks and tighten it if necessary. Clean the pump filter for debris. If using a double-acting cylinder, cap the hoses to check for leaks in the pump and valve. For cold or heavy fluid, drain, flush, and refill the reservoir with a lighter fluid. If the power unit/reservoir capacity is too small, consider using smaller cylinders or a larger reservoir. Also, check for a vacuum in the reservoir by cleaning the vent in the filler plug.
  • S
    smcclainAug 20, 2025
    Why SPX Water Pump builds pressure but cannot maintain it?
    • P
      Patricia BurkeAug 21, 2025
      If your SPX Water Pump builds pressure but can't maintain it, check for external fluid leaks and seal any leaking pipe fittings. If no external leaks are visible, the problem is internal. If you're using a double-acting cylinder, remove it to ensure the leak isn't in the cylinder. Also, inspect the pressure switch seal for leaks and replace the pressure switch if necessary.
  • R
    Ryan CrossAug 25, 2025
    How to troubleshoot SPX Power Team PE18 that does not build to full pressure?
    • C
      castillocindyAug 25, 2025
      If your SPX Water Pump doesn't build to full pressure, begin by replacing the pressure gauge, as it may be faulty. Check for any external leakage and seal faulty pipe fittings. If using double-acting cylinders, remove the cylinder from the pump to check for internal leakage. If the pump then builds full pressure, the cylinder is defective.
  • B
    Beverly JohnsonAug 28, 2025
    Why SPX Power Team PE18 Water Pump motor stalls or overheats?
    • J
      James JonesAug 28, 2025
      If the electric motor of your SPX Water Pump stalls, surges, overheats, or won't start under load, the issue might be low voltage or an electrical cord that's too small. Refer to the electric motor information and electrical cord chart in the Initial Setup section of this manual for guidance.
  • S
    Suzanne GarciaSep 1, 2025
    What causes erratic action in SPX Water Pump?
    • M
      Matthew ThompsonSep 1, 2025
      If your SPX Water Pump is showing erratic action, check for leaks and air in the system and refer to the bleeding procedure. If the issue persists, it may be due to a malfunctioning valve; verify connections and contact an authorized Power Team Service Center.
  • R
    Riley JenkinsSep 4, 2025
    What to do if electrical overload protector keeps tripping on SPX Water Pump?
    • E
      erika59Sep 4, 2025
      If the electrical overload protector of your SPX Water Pump keeps tripping, disconnect the unit from the power supply and have a qualified electrician review the motor and circuit wiring, as it may be wired incorrectly.
  • D
    Dwayne JonesSep 8, 2025
    What causes excess fluid pressure in SPX Water Pump?
    • J
      jenny09Sep 8, 2025
      If the SPX Water Pump delivers excess fluid pressure, replace the faulty pressure gauge.

Summary

Control Valves

Safety Precautions

General Safety Warnings and Definitions

Covers safety symbols, definitions, and general precautions for safe operation.

Component-Specific Safety Guidelines

Safety guidelines for electric motor, hoses, cylinders, and other components.

Initial Setup

Operating Instructions

Cylinder Operation and Pressure Regulation

Using remotes for cylinder control and adjusting the pressure regulating valve.

Pressure Switch Adjustment Procedure

How to adjust the pressure switch to automatically shut off the motor at a set pressure.

General Maintenance

Troubleshooting Guide

Electric Motor and Pump Operation Issues

Troubleshooting common electric motor and pump operational problems.