EasyManua.ls Logo

Srne MC2450N10 - Keys Operation

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick flash
(On:0.1s, off: 0.1s, cycle: 0.2s)
Equalizing
charge
Double flash
(On:0.1s, off: 0.1s, then, On:0.1s,
off: 1.7s, cycle: 0.2s)
Current
limiting
charge
Off
No charge
BAT indication:
Indicator color
Indicator status
Battery status
Green
Steady on
Battery full charge
Yellow
Steady on
Battery voltage normal
Red
Steady on
Battery voltage below
under-voltage point
Quick flash
(On:0.1s, off: 0.1s, cycle:
0.2s)
Battery over-voltage or
over temperature
BAT Type Indication:
Indicator color
Battery type
Green
Sealed lead-acid battery SLD
Yellow
Gellead -acid battery (GEL)
Red
Flooded lead-acid battery (FLD)
Blue
12VLi battery (Default:LiFePo4)
Purple
24VLi battery (Default:LiFePo4)
White
Userself-customized
3.2. Keys Operation
There is a key on the controller, which is used in conjunction with the battery type
indicator for selection of battery type. The specific operation mode is as follows:
In the current operating state, press and hold the key for 8 seconds. The battery type
indicator (the color displayed is that of the previously saved battery type) starts to flash
(the controller turns off charging and other works and enters idle state). At this point,
each time the key is pressed, the battery type indicator changes a color which
corresponds to a battery type. After the battery type is selected, press and hold the key
for 8 seconds again or maintain no operation for 15 seconds. Then, the controller will
automatically save the currently set battery type and enter the normal operating mode;
In addition, if you press and hold the key for 20s, the controller will restore the factory
default parameters.