Any other type of operation must be carried out by authorized Service Centers, requesting original parts.
Tampering with the machine may impair its safety and in any case make the warranty null and void.
9. TROUBLESHOOTING GUIDE
Note: Remove power source and drain tank pressure prior to making any repairs or adjustments.
FAULT CAUSE REMEDY
Leakage of air from the valve of the
pressure switch with the compressor
off.
Checkvalvethat,duetowearor
dirtontheseal,doesnotperformits
function correctly.
Unscrew the hexagonal head of the
checkvalve,cleanthevalveseat
andthespecialrubberdisk(replace
ifworn).Reassembleandtighten
carefully.
Reductionofperformance.Frequent
start-up.Lowpressurevalues.
Excessiveperformancerequest,
check for any leaks from the
couplingsand/orpipes.Intakelter
may be clogged.
Replacethesealsofthetting,clean
orreplacethelter.
The compressor stops and restarts
automatically after a few minutes.
Tripping of the thermal cutout due to
overheating of the motor.
Clean the air ducts in the conveyor.
Ventilate the work area.
Afterafewattemptstorestart,the
compressor stops.
Tripping of the thermal cutout due to
overheatingofthemotor(removal
of the plug with the compressor
running,lowpowervoltage).
Activatetheon/offswitch.Ventilate
the work area. Wait a few minutes.
The compressor will restart
independently.
The compressor does not stop and
the safety valve is tripped.
Irregular functioning of the
compressor or breakage of the
pressure switch.
Remove the plug and contact the
Service Center.