MC521 PRO Control Box
03.23.2017
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204090 REV D 43
Copyright 2017 Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Attachment 8
ANSI/BHMA and UL Compliance Requirements for Swinging and Folding Doors
(Sheet 1 of 2)
Final adjustment and proper operation of the door system
must be and shall be performed in the field.
Note: These instrucons are for informaonal purposes and do not substute for review against the current
revision of the referenced standards. Where a requirement exists in mulple standards, such as the ANSI/
BHMA standard and the UL standard, the more restricve condion applies. Other local codes and re codes
likely exist, and must also be followed.
ANSI/BHMA A156.10 Full/Standard Power Swinging and Folding Door Systems
Full/standard power swinging and folding door systems must be installed and adjusted for compliance with
the current version of ANSI/BHMA A156.10, “American Naonal Standard for Power Operated Pedestrian
Doors”.
Crical aspects of the installaon for compliance with A156.10 include:
Guide rail size, locaon, and type.
Control mat size, layout, molding height, acve areas and sensivity.
Sensor paern size, sensivity, and funcon.
Knowing Act guidelines, secondary acvang zones and double egress swing door requirements.
Entrapment protecon rules including door speeds, forces, and me delays.
Signage. (Decals and applicaon instrucons are provided with the door operator.)
ANSI/BHMA A156.19 Low Energy Swinging Door Systems
Low energy swinging door systems must be installed and adjusted for compliance with the current version of
ANSI/BHMA A156.19, “American Naonal Standard for Power Assist and Low Energy Power Operated Doors”.
Crical aspects of the installaon for compliance with A156.19 include:
Opening mes and force.
Closing mes and force.
Manual opening force.
Time delay.
Signage. (Decals and applicaon instrucons are provided with the door operator.)
UL 325 Compliance
All power operated door systems must be installed in compliance with the current edion of UL 325, “Stan-
dard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems”.

Other manuals for Stanley DE-MC521

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stanley DE-MC521 and is the answer not in the manual?

Stanley DE-MC521 Specifications

General IconGeneral
BrandStanley
ModelDE-MC521
CategoryController
LanguageEnglish

Related product manuals