Values shown as grayed out do not aect moon of the door and may need to be adjusted to suit the applicaon
Attachment 10
Table 2 Recommended Values for Concealed Doors - Motor 2
Index Description Light Weight Door (100lbs) Heavy Weight Doors (350lbs)
Single Pair Single Pair
Low
Energy
Full
Energy
Low
Energy
Full
Energy
Low
Energy
Full
Energy
Low
Energy
Full
Energy
20 Open speed, revoluons per second 9 35 09 25
21 Check speed, revoluons per second 5 7 05 5
22 Stall speed, percent of PWM counts See Aachment 11
23 Open check 20 35 20 45
24 Magic Touch sensivity 00 00 00 00
25 Magic Touch hold open me HH=55
KP=22
HH=40
KP=16
HH=55
KP=22
HH=40
KP=16
26 Hold-open delay HH=55
KP=22
HH=15
KP=06
HH=55
KP=22
HH=15
KP=06
27 Open torque, percent of full torque 25 75 25 75
28 Check torque, percent of full torque 25 40 25 75
29 Stall torque, percent of full torque 25 40 25 25
30 Open Check Boost 10 12 09 12
33 Obstrucon me HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
34 Open Acceleraon Slope 60 60 60 60
35 Open Braking Slope 35 20 20 20
36 Delay before door moon. Motor 2. 00 00 00 00