iQ Control Box
18 Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
01.25.2019
Table 5. Door States
Door State Description
00 Door State is Closed
02 Door State is Opening
04 Door State is in Open Check
06 Door State is Full Open
07 Door State is Closing
09 Door State is in Close Check
10 Open Assist (manual mode door state)
11 Close Assist (manual mode door state)
12 Close Assist (manual mode door state)
14 Door Fault
15 Door State is in Open Stop
16 Door State is in Obstrucon while Closing
17 Door State is in Close Press
19 Lock Release (door state)
NOTE: If the current status code is “Normal operaon—All OK”, the iQ will show the current door state.
Otherwise, the iQ alternates between showing the current status code and the door state.
Final Tune-In Adjustments
1. Refer to ANSI/BHMA A156.10, “Standard for Power Operated Pedestrian Doors,” and aachment 4 and
DETERMINE ANSI and UL door operang requirements.
2. IF Stanguard
TM
threshold sensor is installed, refer to Stanley Access Technologies document No. 203768,
“Stanguard
TM
Threshold Sensor Installaon and Operaon,” and TUNE-IN Stanguard
TM
threshold sensor.
Ensure that the JP301 Jumper is properly installed for StanGuard
TM
Sensors.
3. IF SU-100 moon sensor(s) are installed, refer to Stanley Access Technologies document No. 203957,
“SU-100 Moon Sensor Installaon and Operaon,” and TUNE-IN SU-100 moon sensor(s).
4. IF Optex X Zone T or X Zone ST Sensors are installed, refer to the manufacturer’s installaon and tune-in instrucons.
5. If Hotron HR100 ST sensors are installed, refer to the manufacturer’s instrucons.
6. Aer all changes have been made, cycle the door to have the sengs stored in Non-Volale memory.
Then turn power OFF and then back ON to ensure that all of the sengs are permanently stored.
• Verify that the correct Safety Logic has been selected for Sensor Monitoring and that the JP301 is in the
correct posion.
• DO NOT remove JP301 when Stanguard™ is installed. X Zone T, X Zone ST and HR100 ST monitored sensors
require JP301 to be removed.
7. This step only applies to the Stanley Automac ICU series doors: Refer to ANSI/BHMA A156.38, “American
Naonal Standard for Low Energy Power Operated Sliding and Folding Doors” and Aachment 4 (Page 3 of 3)
and determine ANSI and IBC-2018 door operang requirements.