Table 3. Settings (continued)
Table 3 Settings continued next page.
Index Min
Value
Max
Value
Description Defaults
Single Dual
3 5 99 Open Check Length Open Check Length is the percent of door
length in which the door starts to slow down to
open check speed.
This parameter typically is adjusted based on
door weight and open speed seng.
40 25
4 5 99 Close Check Length Close Check Length is the percent of door length
in which the door starts to slow down to Close
Check Speed.
This parameter typically is adjusted based on
door weight and Close Speed seng.
15 15
5 1 99 Reduced Open
Length
Reduced Open Length is the percent of door length
from the full open posion the door will stop at if in
reduced open mode.
1 1
6 1 99 Hold Open Delay Delay that the door stays open aer all sensors
have cleared (0 to 25 seconds).
15 15
7 0 3 Lock Logic Select to choose desired Lock Logic.
NOTE: Dura-Max 5400 logic is dierent and has
its own two opons:
00 = Fail Safe (unlocked when power
is removed),
01 = Fail Secure (locked when power
is removed),
02 = Dura-Max Fail Safe (unlocked when power
is removed),
03 = Dura-Max Fail Secure (locked when power
is removed).
1 1
8 1 99* Open Torque Open Torque is the torque used during normal
operaon following the end of open startup
length.
This torque must be set to comply with BHMA/
ANSI door force requirements.
This parameter sets the maximum current
available to the motor which is directly
proporonal to the door force. This torque
seng is used in conjuncon with open speed.
40 45