18
7.4 Storage
Warning!
Disconnect the plug from the socket, vent the
appliance and tools connected to it and empty the
condensate.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location which is
not accessible to unauthorized persons.
Always store upright, never tilted!
8. DISPOSAL AND RECYCLING
Pursuant to Directive 2012/19/EU on
waste electrical and electronic equipment (WEEE).
The symbol carrying a crossed-out refuse container
depicted on any equipment or the relative packaging
means that, at the end of its useful life, said product must
bedisposedofseparatelyfromotherwaste.
The user must therefore take said equipment to the
centres specialising in differentiated refuse collection of
electric and electronic equipment or alternatively return
it to the reseller when purchasing a new similar piece of
equipment.
Thanks to differentiated refuse collection, discarded
equipment can be sent to be recycled, treated and disposed
of in an environmentally-friendly manner; this helps
avoiding possible negative effects on the environment
and on health and promotes the re-employment and/or
recyclingoftheequipment’smaterials.
Any unauthorised disposal of the product by the user will
result in the application of the nes provided for by the
regulationsinforce.
9. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
Fault Cause Remedy
Thecompressorstopsandrestarts
automaticallyafterafewminutes.
Trippingofthethermalcutoutdueto
overheatingofthemotor.
Cleantheairductsintheshroud.
Ventilatetheworkarea.
After a few attempts to restart, the
compressorstops.
Trippingofthethermalcutoutdueto
overheating of the motor (removal
of the plug with the compressor
running,lowpowervoltage).
Activate the I/Oswitch(On/Off).
Ventilatetheworkarea.Waitafew
minutes.Thecompressorwillrestart
independently.
Thecompressordoesnotstopand
thesafetyvalveistripped.
Irregular compressor operation or
pressureswitchmalfunction.
Remove the plug and contact the
ServiceCenter.