19
G
B
2. Holdingthehandle,tiltthecompressortowardthedrainvalveso
thatit’ssetinalowerposition.
3. Open gently the drain valve.
4. Keep the compressor tilted until all moisture has been removed.
5. Close the drain valve.
Warning!
The condensation water from the pressure vessel will
contain residual oil. Dispose of the condensation water in an
environmentally compatible manner at the appropriate collection
point.
7.3 Safety valve (ref. G)
The safety valve has been set for the highest permitted pressure of the
pressure vessel. It is prohibited to adjust the safety valve or remove its
seal. Actuate the safety valve from time to time to ensure that it works
whenrequired.Pulltheringwithsufficientforce(fig.5)untilyoucan
hear the compressed air being released. Then release the ring again.
7.4 Storage
Warning!
Pull the mains plug out of the socket and ventilate the appliance
and all connected pneumatic tools.
Switch off the compressor and make sure that it is secured in
such a way that it cannot be started up again by any unauthorized
person.
Warning!
Store the compressor only in a dry location which is not
accessible to unauthorized persons.
Always store upright, never tilted!
8. DISPOSAL AND RECYCLING
Theunitandits accessoriesaremadeofvarioustypesof material,
such as metal and plastic.
Defective components must be disposed of as special waste. Ask your
dealer or your local council.
9. TROUBLESHOOTING GUIDE
Note: Remove power source and drain tank pressure prior to making any repairs or adjustments.
FAULT CAUSE REMEDY
Leakage of air from the valve of the
pressure switch with the compressor off.
Checkvalvethat,duetowearordirtonthe
seal,doesnotperformitsfunctioncorrectly.
Unscrew the hexagonal head of the check
valve,cleanthevalveseatandthespecial
rubberdisk(replaceifworn).Reassemble
and tighten carefully.
Reductionofperformance.Frequentstart-
up. Low pressure values.
Excessiveperformancerequest,checkfor
anyleaksfromthecouplingsand/orpipes.
Intakeltermaybeclogged.
Replacethesealsofthetting,cleanor
replacethelter.
The compressor stops and restarts
automatically after a few minutes.
Tripping of the thermal cutout due to
overheating of the motor.
Clean the air ducts in the conveyor.
Ventilate the work area.
Afterafewattemptstorestart,the
compressor stops.
Tripping of the thermal cutout due to
overheatingofthemotor(removalofthe
plugwiththecompressorrunning,low
powervoltage).
Activatetheon/offswitch.Ventilatethework
area. Wait a few minutes. The compressor
will restart independently.
The compressor does not stop and the
safety valve is tripped.
Irregular functioning of the compressor or
breakage of the pressure switch.
Remove the plug and contact the Service
Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine
may impair its safety and in any case make the warranty null and void.
Warranty and repair.
Intheeventofdefectivegoodsorrequirementsforspareparts,kindlycontactthesalespointwhereyoumadeyourpurchase.