ID07 User Manual ◄ 15
•  Make sure all couplers are wiped clean before 
connection.
•  The hydraulic circuit control valve must be in 
the “OFF” position when coupling or uncoupling 
hydraulic tools. Failure to do so may result in damage 
to the quick couplers and cause overheating of the 
hydraulic system.
•  Always store the tool in a clean dry space, safe from 
damage or pilferage.
•  Make sure the circuit PRESSURE hose (with male 
quick disconnect) is connected to the “IN” port. The 
circuit RETURN hose (with female quick disconnect) 
is connected to the opposite port. Do not reverse 
circuit ow. This can cause damage to internal seals.
•  Always replace hoses, couplings and other parts 
In addition to the Safety Precautions found in 
this manual, observe the following for equipment 
protection and care.
with replacement parts recommended by STANLEY. 
Supply hoses must have a minimum working 
pressure rating of 2500 psi/172 bar.
•  Do not exceed the rated ow. See “Specications” on 
page  17  for  correct  ow  rate  and  model  number. 
Rapid failure of the internal seals may result.
•  Always keep critical tool markings, such as warning 
stickers and tags, legible.
•  Tool repair should be performed by experienced 
personnel only.
•  Make certain that the recommended relief valves 
are installed in the pressure side of the system.
•  Do not use the tool for applications for which it was 
not intended. 
TOOL PROTECTION & CARE
IMPACT MECHANISM MAINTENANCE
If your ID07 shows or starts to show signs of reduced or low pow-
er, it could be a result of lack of grease in the impact mechanism. 
To correct this do the following:
1. Remove the impact 
mechanism by removing the 3 
capscrews holding it on.
2. With the impact mechanism held 
in the palm of your hand ( 3 holes 
in hammer case facing down), lift 
o and remove the hammer case 
along with the anvil leaving just the 
hammer frame, hammers and pins 
left in the palm of your hand.
3. Fill up the cavity hole 
completely with grease (see g 
3) and then put back together 
the hammer case and anvil. 
Note some grease will extrude 
out the end of the hammer 
frame.
4. Install the complete impact mechanism back 
onto the main housing assembly using the 3 
capscrews.
Type of Grease: 
Mobile Delvac Xtreame (Premium 
Lithium Complex Grease) or equivalent.