TOOL OPERATION
Installing a blind rivet (fig. 8)
Read a Smart Touch Screen Operating Manual to know the details of how to use the touch screen.
Please visit our website http://www.stanleyengineeredfastening.com/resource-center/document-library
To install a blind rivet
Place the blind rivet (Y) in the nosepiece (A)
Position the tool (fig.9)
Pull and hold the switch (J) until the rivet is fully set in the application (fig. 10).
When the blind rivet (Y) has been set completely, release the switch (J). The tool will return to its initial
position automatically. The mandrel is automatically dropped into the mandrel collector (W).
If you release the switch (J) before the end of the setting stroke, the tool will immediately return to its initial
position. If the blind rivet (Y) has not been set completely, repeat the previous steps.
In case Auto return mode was enabled, once the tool detects a rivet setting, it will return to its initial position
automatically even if the trigger remains holding.
Reset function (fig.9)
If the tool does not move to its initial position after releasing the switch or stops during the setting stroke, reset
the tool to home by quickly pulling and releasing the switch (J). If this does not resolve the issue, remove the
battery, re-insert and then repeat the prior step. If the issue persists, contact your local service representative.
Emptying the mandrel collector (W) (fig. 6)
The mandrel collector is used to collect the waste mandrels. The mandrel collector must be emptied depending
on the size of the blind rivets used.
Nom. Rivet Dia.
Approx. Capacity (PB2500 Smart)
2.4 mm [3/32”]
600
3.2 mm [1/8”]
360
4.0 mm [5/32”]
200
4.8 mm [3/16”]
150
6.4 mm [1/4”]
Not applicable
Tilt the tool back to allow all waste mandrels to fall into the mandrel collector.
Open the mandrel collector (W) by sliding the Collector Lock (D) towards the nose housing nut (C) and raise the
cover (E).
Empty the waste mandrels into an appropriate recycling container or waste bin
To close the mandrel collector (W), lower the cover (E) until the Collector Lock (D) clicks into place.