Tighten SA Nose housing onto the
thread of Mast housing by hand.
9.
Operation Test and Appearance check
Operation Check
Set 20 rivets of 4.8mm (3/16”) Stainless
rivet and 10 Aluminum rivet to check
followings:
The tool(Jaws) does not slip.
Rivet setting is done in one stroke.
There are no protruding mandrels.
There is no abnormal noise.
The next rivet introduced to the front
of the tool is inserted smoothly.
The jaws do not bite.
The waste mandrel is ejected to the
Collector correctly.
The collector shutter operates
normally
(Open Close)
Appearance check
Any scratches on the housings
Loose components and screws
Any oil spots on the housings
Peeling of the outer mold
(Rubber grip)
SA Nose housing
Mast housing