1. Explosive gases can be emitted during the charging duration.
2. NEVER smoke or allow a spark or flame in the vicinity of a battery.
3. Never charge a frozen battery.
4. Remove personal metal items such as rings, bracelets, necklaces and watches when working
with a lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to weld
a ring or the like to metal, causing a severe burn.
5. Be extra cautious, to reduce the risk of dropping a metal tool onto the battery. It might spark or
short-circuit the battery or other electrical part that may cause an explosion.
6. To prevent sparking, NEVER allow clamps to touch together or contact the same piece of metal.
7. Wear protective clothes, gloves and goggles to use the charger. Avoid touching your eyes while
working near the battery.
8. If battery acid contacts your skin or clothing, immediately wash the area with soap and water. If
acid enters your eye, immediately flood the eye with cold running water for at least 10 minutes and
get medical attention right away.
9. If battery acid is accidentally swallowed, drink milk, the whites of eggs or water. DO NOT induce
vomiting. Seek medical attention immediately.
10. Read, understand and follow all instructions for the charger, battery, vehicle and any equipment
used near the battery and the charger.
11. Determine the voltage of the battery by referring to the vehicle owner’s manual and make sure
that the output voltage of the charger is correct.
2. Description
1. Display - Control panel
2. Power LED - Green: the charger is connected to the AC power (mains).
3. Fault LED - Red: there is an issue with the battery. Check the error indication on the display.
4. Selection push button to choose the charging parameters on the control panel.
5. Output lead: Cable with clamps 30A - Ref: SXAE00029.
6. Output lead: Cable with rings 6mm and protective, insulating, watertight cap.
2.1. Control panel
Display
Description
Mode for 6V battery.
Mode for 12V battery.

Table of Contents