51
3.4. Control Font Usage
The Control device font is used to provide for control within the span of a single document.
This font is not used for character printing.
3.4.1. Control Font list
The following table is the list of the supported control device fonts.
Character Function
A Open cash drawer 1 for 50 mSec.
B Open cash drawer 1 for 100 mSec.
C Open cash drawer 1 for 150 mSec.
D Open cash drawer 1 for 200 mSec.
E Open cash drawer 1 for 250 mSec.
d Open cash drawer 2 for 200 mSec.
6 LF
7 CR
F Full Cut
P Partial Cut
a Set Left Alignment
b Set Center Alignment
c Set Right Alignment
e Set 3mm line feed spacing (1/8 inch)
f Set 4mm line feed spacing (1/6 inch)
g Select USA international character set
h Select France international character set
i Select Germany international character set
j Select England international character set
k Select Denmark I international character set
l Select Sweden international character set
m Select Italy international character set
n Select Spain I international character set
o Select Japan international character set
p Select Norway international character set

Table of Contents