EasyManua.ls Logo

Starr Instruments TGD-100 User Manual

Starr Instruments TGD-100
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TGD-100
Ultrasonic Thickness Gauge
Instruction Manual
VER:3.1
Question and Answer IconNeed help?

Do you have a question about the Starr Instruments TGD-100 and is the answer not in the manual?

Starr Instruments TGD-100 Specifications

General IconGeneral
BrandStarr Instruments
ModelTGD-100
CategoryMeasuring Instruments
LanguageEnglish

Summary

2 Product Specifications

2.1 Technology parameter

Lists detailed technical specifications of the ultrasonic thickness gauge, including range, accuracy, and power.

3 Operation

3.1 Preparation for measurement

Steps for powering on the instrument and connecting the probe before taking measurements.

3.2 Adjusting sound velocity

Guide on how to set and adjust the sound velocity parameter for accurate thickness readings.

3.4 Measurement of thickness

Step-by-step process for performing thickness measurements on a material.

3.5 Zero calibration

Details the procedure for performing a zero-point calibration using a standard test block.

3.6 Measurement of sound velocity

Explains how to measure and set the sound velocity of a material using a known thickness.

3.7 Setting alarm thickness limits

How to configure high and low limits to trigger audible alarms for out-of-spec measurements.

5 Measuring technology

5.9 Reference test piece

Importance and selection criteria for using reference test pieces for calibration.

6 Preventing errors in measurement

6.1 Ultra-thin Material

How to handle measurement errors when dealing with very thin materials.

6.7 Abnormal Readout of Thickness

Identifying and addressing abnormal thickness readings caused by defects.

7 Attention

7.5 Absolutely avoid collision and moisture.

Critical safety warning regarding physical damage and water exposure.

8 Maintenance

8.1 Error Measurement Troubleshooting

Guidance on addressing significant measurement errors by referring to relevant chapters.

8.2 Contacting Manufacturer for Issues

Lists specific problems requiring professional support from the dealer or manufacturer.

8.3 User Maintenance Restrictions

States that the user should not attempt to disassemble or repair the high-tech instrument.

9 Operation to restore the factory parameters

9.1 Restore Factory Settings

Step-by-step guide to reset the instrument to its default factory parameters.