12
742.114 | 14.50
EN
Display Legend Terminal layout
1 swimming pool, 1 collector array
R2
T1
T2
T1: collector array sensor
T2: swimming pool sensor
R2: solar circuit pump
1,
2,
R2, N, PE (0–10 R2,
2)
)
1 swimming pool with external heat exchanger, 1 collector array
R1
R2
T1
T2
T3
T1: collector array sensor
T2: swimming pool sensor
T3: external heat exchanger sensor
R1: solar circuit pump
R2: swimming pool loading circuit
pump
1,
2,
3,
R1, N, PE (0–10 R1,
1)
)
R2, N, PE (0–10 R2,
2)
)
1 storage tank, 1 swimming pool, 1 collector array (pump-controlled)
T1
T2
T3
R1
R2
T1: collector array sensor
T2: lower storage tank sensor
T3: swimming pool sensor
R1: storage tank solar circuit pump
R2: swimming pool solar circuit pump
1,
2,
3,
R1, N, PE (0–10 R1,
1)
)
R2, N, PE (0–10 R2,
2)
)
1 storage tank, 1 swimming pool, 1 collector array (pump-/valve-controlled)
R1
R2
T1
T2
T3
T1: collector array sensor
T2: lower storage tank sensor
T3: swimming pool sensor
R1: solar circuit pump
R2: storage tank switching valve
6)
1,
2,
3,
R1, N, PE (0–10 R1,
1)
)
R2, N, PE
Tab. 1: Terminal pin assignments
1)
Terminal pin assignments for 0–10 V-controlled high-efficiency pumps: The power supply must
be connected to output R1 (N, PE); the control cable for the pump electronics must be con-
nected to 0–10
R1 and
2)
Terminal pin assignments for 0–10 V-controlled high-efficiency pumps: The power supply must
be connected to output R2 (N, PE); the control cable for the pump electronics must be con-
nected to 0–10
R2 and .
3)
Installation regulation: When no power is supplied to the switching valve, then no flow occurs
through the storage tank.
4)
Installation regulation: When no power is supplied to the switching valve, then the lower part
of the storage tank (T2) is loaded.
5)
Installation regulation: When no power is supplied to the switching valve, then the first priority
storage tank (T2) is loaded.
6)
Installation regulation: When no power is supplied to the switching valve, then the storage
tank (T2) is loaded.