34
11� Technical specifications
IS3180
IS3360 / IS3360MX
IS345 IS345MX
Dimensions
(L×W×H)
126× 65mm
95×95× 65mm
124× 78mm
94×94× 78mm
Output Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
Minimum switching load
2000 W
1500 W
1000 VA
400 VA
1000 VA
2000 VA
100 W
300 W
600 W
176 μF
100mA @12VAC/DC
Mains power
supply
220-240 V, 50 / 60 Hz max. 2.5 mm
2
Angle of
coverage
180° with 90°
angle of perture
360° with 180°
angle of aperture
180° with 45°
angle of perture
180° with 45°
angle of perture
Reaches Basic
setting 1:
max. 8 - 20 m
tangential;
temperature
stabilised
Basic
setting 2:
max. 4-8 m:
temperature
stabilised
+ precision
adjustment by
repositioning
the lens and
using shrouds
IS3360
max. 20 m
tangential;
temperature
stabilised
IS3360 MX
max. 18 m;
temperature
stabilised
+ precision
adjustment
using shrouds
max. 23×6m
(tangential),
max. 12×6 m
(radial);
temperature
stabilised
+ precision
adjustment
using shrouds
max. 30×4m
(tangential)
mounted at a
height of 14 m;
temperature
stabilised
+ precision
adjustment
using shrouds
Detection levels 7 11 5 5
Switching zones 448 1416 280 120
Time setting 5s - 15min + pulse mode (approx. 2s)
Twilight setting 2-1000 lux + teach mode
Manual override
(permanent light)
selectable (4 h)
IP rating Surface-mounted: IP 54 Concealed: IP 20
Temperature
zone
-20°C to +50°C
Surface-mounted installation, round Ø
Surface-mounted installation, square
Concealed installation, round Ø
Concealed installation, square