STEINEL IS 3360 - Unwanted activation and LED indicators

STEINEL IS 3360
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Malfunction Cause Remedy
Sensor responds
when it should not
n Wind moving trees
and bushes in the
detection zone
n Cars in the street are
being detected
n Sunlight is shining on
the lens
n Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans,
open windows
n Dazzle guard active
n Sensor near Wi-Fi or
other wireless commu-
nication sources
n Change detection zone
n Change detection zone
n Mount sensor
in a sheltered place or
change detection zone
n Change detection zone,
mount in a different
place
n Switch OFF manually
at pushbutton/switch
n No movement detected
within the selected
stay-ON time + 60 sec
(dazzle guard)
n Install at least 2 m away
from the wireless com-
munication source
LED flashes once every 15 s
n Load connected
is too high
n Reduce load or use
contactor