User Assembly Manual
Blueleaf, Charwood House, Oakhurst Business Park,
SOUTHWATER, West Sussex, RH13 9RT, UK
www.steiss.co.uk
HOLD\RELEASE FUNCTION
1. When the person is on the scale, press the HOLD\RELEASE key.
2. When the person gets off the scale the weight will remain the same.
The zero flag will not turn on.
3. At this stage the ZERO key will not work. The only way to return to zero
from here is to press the HOLD\RELEASE key once more.
TARE FUNCTION:
1. When the weight is below the ASTART parameter value press the TARE key.
2. The default tare value is displayed (factory programmed at 33.0 lb.\15.0
kg), while the zero is flashing.
3. UP/DOWN key is used to adjust the value.
4. Press enter start the tare function. NET annunciator will be turned on
instead of the GROSS annunciator.
MANUAL TARE
1. When the weight is above the ASTART parameter value press the TARE
key.
2. The tare will be activated with the value that was displayed at the time of
the tare activation.
3. NET annunciator will be turned on instead of the GROSS annunciator.
RS232 Communication
The Scale Communication Protocol is used to send data between the scale and the
PC or printer it is connected to. The baud-rate of the communication is
programmable, the default value is 9600. The remaining communication
parameters are fixed, 8 data bit, 1 stop bit and no parity.