Classic Series www.stenner.com
10
FLOW RATE OUTPUTS CLASSIC 100 DUAL CONTROL
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
*
Duckbill check valve included with pumps rated 100 psi (6.9 bar) maximum.
Model
Item Number Maximum Pump Feed Rate Control Setting
Prefix psi / bar Tube L12345678910
100MDCHP5* 100DH1 100 / 6.9
100MDC1 100DL1 25 / 1.7
100MDCHP20* 100DH2 100 / 6.9
100MDC2 100DL2 25 / 1.7
100MDC3 100DL3 25 / 1.7 3 1.1 2.2 4.4 6.6 8.8 11.0 13.2 15.4 17.6 19.8 22.0
100MDC4 100DL4 25 / 1.7 4 1.7 3.5 7.0 10.5 14.0 17.5 21.0 24.5 28.0 31.5 35.0
100MDC5 100DL5 25 / 1.7 5 2.5 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0
Innermost Pump Head – Gallons per Day
2 0.5 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
1 0.2 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0
Model
Item Number Maximum Pump Feed Rate Control Setting
Prefix psi / bar Tube L12345678910
100MDCHP5* 100DH1 100 / 6.9
100MDC1 100DL1 25 / 1.7
100MDCHP20* 100DH2 100 / 6.9
100MDC2 100DL2 25 / 1.7
100MDC3 100DL3 25 / 1.7 3 3.3 6.6 13.3 20.0 26.6 33.3 40.0 46.6 53.3 60.0 66.6
100MDC4 100DL4 25 / 1.7 4 5.1 10.6 21.2 31.8 42.4 53.0 63.6 74.2 84.8 95.4 106.0
100MDC5 100DL5 25 / 1.7 5 7.6 15.1 30.3 45.4 60.6 75.7 90.8 106.0 121.1136.3 151.4
Innermost Pump Head – Liters per Day
2 1.5 3.0 6.1 9.1 12.1 15.1 18.2 21.2 24.2 27.3 30.3
1 0.6 0.9 1.8 2.7 3.6 4.5 5.5 6.4 7.3 8.2 9.1
DETERMINE FLOW RATE OUTPUTS FOR EACH PUMP HEAD
Use the innermost pump head flow rate outputs to determine the output for each pump head.
Both feed rate controls (FRC) on setting 10 = maximum flow rate capacity of the pump.
Innermost Pump Head
L=5%, 1-10 = approx. 10% of maximum innermost output
Outermost Pump Head
Outermost Output = (Outermost FRC Setting %) x (Innermost Output)
Example
100MDC5 with Innermost FRC setting on 4
1. Innermost FRC setting 4 = 20 gpd
2. If outermost FRC is set on 3, then outermost output is 30% of innermost output; 0.3 x 20 gpd = 6 gpd
3. Outermost = 6 gpd, Innermost = 20 gpd, Total Pump Output = 26 gpd
Approximate Outputs @ 50Hz
Approximate Outputs @ 60Hz