Phone 01933 677911
Fax 01933 677916
STEPHILL GENERATORS
Drawing Number
SW16008
Drawn
R Golding
Last Number Used
33
Fuel level sender wiring changed.
Issue
D
Date
21/02/12
Revision
Description
Wiring diagram Deep sea 3110 Kubota Z602
D722
12 WAY CONNECTOR
18
29
4
25
17
All cable except battery cable to be 1.5mm White unless stated. Low
fuel level switch optional.
Note
1 = Cable numbers
(1) = Terminal numbers
R1 = 60A Relay
R2 - R4 = 30A Relay
Legend
(10)
(7)
(4)
(1)
(12)(11)
(8) (9)
(5)
(2)
(6)
(3)
LOOM CONNECTOR
CABLE ENTRY VIEW
FUEL GAUGE
18
(12)
1
18
33
17
(6)
16
(7)
29
(8)
FUEL PUMP PRIME
2 33
33 33
(5)
4
(9)
(2)
5
2A RE-SET
2
25
(3)
7
7
25
(1)
16
TEMP SWITCH
17 1
OIL SWITCH
16 1
FUEL LIFT PUMP
Red
24
1
Black
1
BATTERY ISOLATOR
2.5mm
2.5mm
6mm
26
R3
32
19
1
31
5
20
23
R2
4
19
29
R1
5
29
+
29
25mm
25
SWITCH
40A
60A
19
23
25
25
6mm
4mm
2.5mm
1
-
STARTER MOTOR
25mm
20
26
GLOW PLUG
25
CHARGE ALTERNATOR
6mm
25
7
3
CHARGE ALTERNATOR
OIL PRESSURE
EMERGENCY STOP
TEMP SWITCH
DEEP SEA 3110
A/C Supply
1A RE-SET
8
13
14
15
17
16
12
11
1.5mm BLUE
1.5mm BROWN 9
10
BATTERY +VE
BATTERY -VE
FUEL SOLENOID
12345679 8
START SOLENOID
REMOTE START
REMOTE START
13 1 -VE
2 +VE
2
PRE HEAT
1
EMERGENCY STOP
12 1
29 1
1
1
1
1
2.5mm
2.5mm
6mm
GLOW PLUGS
START SOLENOID
STOP SOLENOID
1
3
12
2
1
4
32
3
STOP SOLENOID
31
2.5mm
R4
33
19
29
24
29
RUN SOLENOID
24
19
2
3
33
3232
(10)
2
3
24
DYNAMO
7
33
Blue
Blue
1
19
21
22
REGULATOR
21
22
33
7
1
2
3
7
6
9
10
8
5
4
BACK OF SOCKET
3
2
1
4
5
8
10
9
6
7
BACK OF PLUG
(3) (1) (2) Socket pins
FUEL LEVEL SENDER
18 1
Fuel level sender wiring changed at plug.
C
30/01/12
Fuel gauge wiring changed.
07/01/13
E