Step 11: Use the up or down keys to select the global submenu gLbL will be in the upper dis
play and SEt will be in the lower display. Press the advance key to enter the global
menu.
Parameter Value Description
11-1 C_F F display units
Advance key
11-2 AC.LF 60 AC line frequency
Advance key
Step 12: After pressing the advance key at parameter AC.LF will advance you back to
parameter C_F. Press the infinity key once to return to the global submenu.
Step 13: Use the up or down keys to select the communication submenu. Cor7 will be
in the upper display and SEt will be in the lower display. Press the advance
key to enter the communications submenu.
Parameter Value Description
13-1 Ad.5 1 Address Standard Bus
Advance key
Step 14: Pressing the advance key on parameter Ad.5 will advance you back to the same
parameter, Ie. you will still see parameter Ad.5 displayed. Press the infinity key
once to return to the communications sub menu.
Step 15. Press the infinity key to return to the Home page.
Step 16. From the Home page, press both the up and down keys for (3) seconds, Ai will
appear in the upper display and oPEr will appear in the lower display.
Operations Page
Step 17: Once F1i is in the upper display and oPEr is in the lower display, you are
at the Operations menu. If not, press the infinity key to return to the Home
menu and redo step 16.
Step 18: Press the up and down keys until LooP is in the upper display and oPEr is
in the lower display. Press the advance key to enter the LooP sub menu.
Parameter Value Description
(use the up or down keys to change values)
18-1 C.r7 auto control mode
Advance key
18-2 C.SP 75 closed loop setpoint
Advance key