EasyManua.ls Logo

STIEBEL ELTRON DCE 10 Plus - Page 19

STIEBEL ELTRON DCE 10 Plus
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Specication
ENGLISH
www.stiebeleltronamericas.com DCE Plus| 19
16.7 Data table
DCE 10 Plus DCE 13 Plus DCE 15 Plus
238150 238151 238152
Electrical data
Rated voltage V 208 220 240 208 220 208 220 240
Rated output
1
kW 5.4/7.2 6.0/8.0 7.2/9.6 11.8 13.2 9.0/10.7 10.0/12.0 12.0/14.4
Rated current A 25.8/34.4 27.3/36.4 30.0/40.0 56.7 60.0 43.3/51.6 45.5/54.5 50.0/60.0
Recommended circuit breaker size
2
A 30/35 30/40 30/40 60 50/60
Min. recommended wire size
3
(AWG copper) 8 6 6
Frequency Hz 50/60 50/60 50/60
Phase 1/N/GND | 2/GND 1/N/GND | 2/GND 1/N/GND | 2/GND
Resistivity ρ15 ≥ Ω cm 1100 1100 1100
Conductivity σ15 ≤ μS/cm 910 910 910
Max. mains impedance at 50Hz Ω 0.0407 0.0385 0.0353 0.0248 0.0234 0.0272 0.0257 0.0235
Connections
Water connection ½˝ NPT ½˝ NPT z˝ NPT
Application limits
Max. permissible pressure MPa 145 (1) 145 (1) 145 (1)
Max. inlet temperature for reheating °F (°C) 131 (55) 131 (55) 131 (55)
Temperature setting range °F (°C) 68–140 (20–60) 68–140 (20–60) 68–140 (20–60)
Values
Max. inlet temperature (e.g. pasteurization) °F (°C) 158 (70) 158 (70) 158 (70)
Activation rate gpm (l/min) 0.264 (1.0) 0.264 (1.0) 0.264 (1.0)
Hydraulic data
Nominal capacity gal (l) 0.07 (0.277) 0.07 (0.277) 0.07 (0.277)
Versions
Adjustable connected load Yes No Yes
Protection class 1 1 1
Insulating block Plastic Plastic Plastic
Heating system Direct Coil
Direct Coil
Direct Coil
Cover and back panel Plastic Plastic Plastic
Color White White White
IP rating IP 24 IP 24 IP 24
Dimensions
Height in (mm) 14
5
/
8
˝ (372) 14
5
/
8
˝ (372) 14
5
/
8
˝ (372)
Width in (mm) 8
9
/
16
˝ (217) 8
9
/
16
˝ (217) 8
9
/
16
˝ (217)
Depth in (mm) 4
5
/
16
˝ (109) 4
5
/
16
˝ (109) 4
5
/
16
˝ (109)
Weights
Weight lb (kg) 5.5 (2.50) 5.5 (2.50) 5.5 (2.50)
1
For units with adjustable power output, factory default setting is jumper position 2 [high]
2
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under
load.
These are our recommendations. Check local codes for compliance if necessary.
Note
The water heater conforms to IEC 61000-3-12.

Table of Contents

Related product manuals