INSTALLATION
Specication
18 | DCE Plus www.stiebeleltronamericas.com
Power output in kW 38°C DHW output in l/min
Rated voltage Cold water inlet temperature
208V 220V 240V 5°C 10°C 15°C 20°C
5.4 2.3 2.8 3.4 4.3
7.2 3.1 3.7 4.5 5.7
6.0 2.6 3.1 3.7 4.8
8.0 3.5 4.1 5.0 6.3
7.2 3.1 3.7 4.5 5.7
9.6 4.2 4.9 6.0 7.6
11.8 5.1 6.0 7.3 9.4
13.2 5.7 6.7 8.2 10.5
9.0 3.9 4.6 5.6 7.1
10.7 4.6 5.5 6.6 8.5
10.0 4.3 5.1 6.2 7.9
12.0 5.2 6.1 7.5 9.5
12.0 5.2 6.1 7.5 9.5
14.4 6.2 7.3 8.9 11.4
Power output in kW 50°C DHW output in l/min
Rated voltage Cold water inlet temperature
208V 220V 240V 5°C 10°C 15°C 20°C
5.4 1.7 1.9 2.2 2.6
7.2 2.3 2.6 2.9 3.4
6.0 1.9 2.1 2.4 2.9
8.0 2.5 2.9 3.3 3.8
7.2 2.3 2.6 2.9 3.4
9.6 3.0 3.4 3.9 4.6
11.8 3.7 4.2 4.8 5.6
13.2 4.2 4.7 5.4 6.3
9.0 2.9 3.2 3.7 4.3
10.7 3.4 3.8 4.4 5.1
10.0 3.2 3.6 4.1 4.8
12.0 3.8 4.3 4.9 5.7
12.0 3.8 4.3 4.9 5.7
14.4 4.6 5.1 5.9 6.9
16.4 Application areas/conversion table
Electrical resistivity and electrical conductivity.
Standard specifica-
tion at 15°C
20°C
25°C
Resis-
tivity
ρ≥
Conductivity σ
Resis-
tivity
ρ≥
Conductivity σ
Resis-
tivity
ρ≥
Conductivity σ
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
1100 91 910 970 103 1031 895 112 1117
16.5 Pressure drop
Sizing the pipework
When calculating the size of the pipework, a water heater pressure
drop of 14.5 psi (0.1MPa) is recommended.
16.6 Fault conditions
In the event of a fault, temperatures up to 176 °F (80 °C) at a pres-
sure of 145 psi (1.0 MPa) can occur briefly in the installation.