INSTALLATION
Installation
14 | DCE Premium www.stiebeleltronamericas.com
10.1 Standard non-concealed installation
10.1.1 Removing the cover
D0000073641
f Open the water heater by undoing the screw and lifting up
the cover.
10.1.2 Preparing the power cable
B
A
D0000077179
f Prepare the power cable.
Position for non-concealed
installation
Dimension A Dimension B
Bottom, center 1½˝ (30 mm) 4¾˝ (120 mm)
Bottom, left side of water heater ½˝ (20 mm) 3½˝ (90 mm)
Bottom, right side of water heater ½˝ (20 mm) 3½˝ (90 mm)
Top, right side of water heater ½˝ (20 mm) 3
1
/
8
˝ (80 mm)
Position for concealed instal-
lation
Dimension A Dimension B
Bottom ½˝ (20 mm) 3½˝ (90 mm)
Top ½˝ (20 mm) 3
1
/
8
˝ (80 mm)
10.1.3 Preparation
f Cut a hole in the cable grommet to fit the selected connecting
cable. Fit the cable grommet.
10.1.4 Mounting the water heater
f Mark the 4drill holes, referencing their position on the water
heater rear cover.
f Drill the holes and secure the water heater using suitable
fixing materials (screws and wall anchors are not part of the
standard delivery): Countersunk screw, Ø4.5mm, max. di-
ameter of screw-head 9mm.
D0000073844
f Connect braided steel flex connectors (recommended,
not supplied) or other pipework to the twin ½˝ NPT male
connectors.
f Open the shut-off valve in the cold water inlet line.
10.2 Electrical connection
WARNING Electrocution
Before beginning any work on the electric instal-
lation, be sure that main breaker panel switches
are “Off” to avoid any danger of electric shock. All
mounting and plumbing must be completed before
proceeding with electrical hook-up. Where required
by local, state or national electrical codes the circuits
should be equipped with a “ground fault interrupter.
The unit must be properly grounded in accordance
with state and local codes, or in absence of such
codes, in accordance with national electric code or the
Canadian electric code. Failure to electrically ground
the product could result in serious personal injury or
death.
WARNING Electrocution
The connection to the power supply is only permissible
as a permanent connection in conjunction with the re-
movable cable grommet. Ensure the water heater can
be separated from the power supply by an isolator that
disconnects all poles with at least 1/8˝ (3mm) contact
separation.
!
CAUTION: DO NOT INSTALL IN A BATH ENCLOSURE OR
SHOWER STALL OR CONNECT TO A SALT-REGENERATED
WATER SOFTENER OR A WATER SUPPLY OF SALT
WATER
FOR USE ON AN INDIVIDUAL BRANCH CIRCUIT ONLY
CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED
BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER
USE COPPER CONDUCTORS ONLY
USE BONDING CONDUCTOR IN ACCORDANCE WITH THE
CANADIAN ELECTRICAL CODE, PART I
!
Supply this appliance only from a grounded system. A
green terminal (or a wire connector marked “G”, “GR”,
“GROUND”, OR “GROUNDING”) is provided for wiring
the appliance. To reduce the risk of electric shock,
connect this terminal or connector to the grounding
terminal of the electric service or supply panel with a
continuous copper wire in accordance with the electri-
cal installation code.
!
Material losses
Observe the type plate. The specified rated voltage must
match the supply line voltage.
!
Material losses
The DCE 13 Premium must only be connected to a 208V or
220V electrical supply. Connecting the DCE 13 Premium
to a 240V electrical supply will permanently damage the
unit and void the factory warranty.