32 | DEL SL electronic LCD www.stiebel-eltron.com
INSTALLATION
Installation
Power cable for finished walls
Cut or break out the required entries in the back panel and
appliance cover cleanly (for positions, see chapter "Specifica-
tion/ Dimensions and connections"). If necessary, use a file.
Route the power cable through the cable grommet. Connect
the power cable to the mains terminal.
Note
This type of connection changes the protection rating of
the appliance.
Change the type plate. Cross out "IP 25" and mark
the box "IP 24". Please use a ballpoint pen to do this.
Large cross-section for electrical connection from below
If you use cables with a large cross-section, you can fit the cable
grommet after the appliance has been installed.
1.
3.
4.
2.
26�02�02�1124
Before installing the appliance, use a screwdriver to push out
the cable grommet.
Slide the cable grommet over the power cable. For this, use
the installation aid. If the cross-section is >6mm², enlarge
the hole in the cable grommet.
Push the cable grommet into the back panel.
Connecting a load shedding relay
Install the load shedding relay in the distribution board in conjunc-
tion with other electric appliances, e.g. electric storage heaters.
The relay responds when the instantaneous water heater starts.
The load shedding relay is available as an accessory.
!
Material losses
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the
appliance (see chapter "Specification/ Wiring diagram").
Water installation on finished walls
Suitable pressure-tested taps can be ordered as accessories.
19
24
5 Nm
18 Nm
D0000033104
1
2
1 Water plug
2 Pressure tap for finished walls
Fit the water plugs with gaskets to seal the in-wall connec-
tion. All pressure taps listed in the accessories are supplied
with plugs and gaskets as part of the standard delivery.
Install the tap.
Place the lower section of the back panel under the tap con-
nection pipes. Slide the lower section of the back panel into
place.
Fit the connection pipes to the appliance.
Water installation for finished walls with solder/ compression
fitting
With the solder fitting or compression fitting accessories you can
connect both copper and plastic pipes. For installation, prepare
the appliance cover, see chapter "Water installation on finished
walls, fitting the appliance cover".
The solder fitting with threaded fitting is suitable for 12mm cop-
per pipes.
Push the union nuts over the connection pipes.
Solder the inserts to the copper pipes.
Slide the lower section of the back panel under the tap con-
nection pipes. Push the lower section of the back panel into
place.
Fit the sealing elements on to the connection pipes.
Fit the connection pipes to the appliance.
Note
Observe the tap manufacturer's instructions.

Table of Contents