WWW.STIEBEL-ELTRON-USA.COM DHC | 5
INSTALLATION
WATER CONNECTIONS
26�02�02�033126�0202�1355
6. Water connections
1. All plumbing work must comply with national and applicable
state and local plumbing codes.
2. A pressure reducing valve must be installed if the cold water
supply pressure exceeds 150 PSI (10 bar).
3. Make certain that the cold water supply line has been flushed
to remove any scale and dirt.
4. Install isolating valve in cold water line as shown in illust-
ration. This allows the unit to be isolated for maintenance
purposes.
5. Cold water connection (inlet) is on the right side of the unit,
hot water connection (outlet) is on the left side of unit.
Note
Excessive heat from soldering on copper pipes near the
DHC may cause damage.
6. Tankless water heaters such as the DHC are not required to
be equipped with a Pressure and Temperature Relief Valve
(PTRV). If the local inspector will not pass the installation
without a PTRV, it should be installed on the hot water outlet
side of unit.
7. In case you are connecting to 1/2˝ water pipe, solder 1/2˝
NPT tapered female adapter by copper on ends of cold and
hot water lines. In case you are connecting to 3/8˝ water
pipe, use a 1/2˝ female pipe thread by 3/8˝ compression
adapter. Braided flexible connectors will work as well.
Connect cold and hot water lines to the unit.
8. When all plumbing work is completed, check for leaks and
take corrective action before proceeding.
7. Electrical connection
!
WARNING:
Before beginning any work on the electric installation,
be sure that main breaker panel switches are "off"
to avoid any danger of electric shock. All mounting
and plumbing must be completed before proceed-
ing with electrical hook-up. Where required by local,
state or national electrical codes the circuits should be
equipped with a "ground fault interrupter".
The unit must be properly grounded in accordance
with state and local codes, or in absence of such
codes, in accordance with national electric code or the
Canadian electric code. Failure to electrically ground
the product could result in serious personal injury or
death.
1. All electrical work must comply with national and applicable
state and local electrical codes.
2. The DHC should be connected to a properly grounded dedi-
cated branch circuit of proper voltage rating. In installa tions
with several DHC units, each unit requires an independent
circuit. Please refer to the technical data table for the correct
wire and circuit breaker size.
3. The wire must be fed through the rubber seal located bet-
ween the hot and cold water connections. Then feed wires
through strain relief clamp and tighten clamp down on wire.
The "live" wires must be connected to the slots on the termi-
nal block marked N and L (DHC 3-1 only) or L and L (all other
versions). The ground wire must be connected to slot mar-
ked with the ground symbol.
4. Reinstall plastic cover.
4˝ (100 mm)
26�02�02�0469

Table of Contents

Other manuals for STIEBEL ELTRON DHC 8-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON DHC 8-2 and is the answer not in the manual?

STIEBEL ELTRON DHC 8-2 Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelDHC 8-2
CategoryWater Heater
LanguageEnglish

Related product manuals