4. Fault elimination for the user
2.6 First operation
(Only to be carried out by a qualified
installer)
Before switching on, set the rotary
temperature control to "Min". Open
water valve until the pipework and the unit
are free of air.
- Check the operation of the water heater.
Warning : Open hot water faucet
for a few minutes until water flow is
continuous and all air is purged from water
pipes.The unit's plastic cover must be
installed before the circuit breaker is turned
on.
Handing over the unit
Explain to the user how the unit works and
familiarise him or her with its use.
- Advise the user about possible hazards
(high water temperature)
- Hand over these instructions, to be kept
in a safe place.
2.7 Service note
When carrying out any work,
isolate the unit from the mains
and shut off the water connection.
Fault Cause Rectification
No hot water - The water flow volume required for the
unit to turn on has not been reached.
- The shower head is blocked with dirt or - Clean shower head or remove limescale.
limescale.
- Flow volume too low - Increase flow volume.
- Circuit breaker off - Turn breaker on
- Safety thermal cut-out trip - Reset thermal cut-out
2.5 Installing the unit
1. Flush the cold water pipe thoroughly.
2. Fit a secure connection cable (1)
(ensure dimensions are correct).
3. Release cover securing screw (11).
4. Remove cover.
5. Determine the position of the drill holes
and drill the holes. Insert the wall plugs
and screw in the screws (ensure screw
insertion depth is correct) (12).
6. Feed the connection cable through the
cable seal (7) in the rear wall. Guide the
unit over the wall securing screws and
slide it downwards .
7. Fit the filter and the washer (14) to the
cold water inlet of the unit (5). Tighten
the union nut to the warm water outlet of
the unit. (4)
8. Straighten the unit and tighten the screws.
9. Connect the electrical supply.
10. Fit the cover and secure with the screw.
11. Turn the rotary control to the left and
right (internal setting lever will engage).
For guarantees please refer to the
respective terms and conditions of supply
for your country.
The installation, electrical connec-
tion and first operation of this
appliance should be carried out by a
qualified installer.
The company does not accept liability for
failure of any good supplied which have not
been installed and operated in accordance
with the manufacture's instructions.
The unit is not being switched on. Electricity The water flow volume required for the unit
supply and flow available. to turn on has not been reached.
- Filter in the cold water connection pipe - Clean the filter after shutting off the cold
blocked with dirt. water intake.
3. Guarantee
- Clean the filter
Disconnect the union nut (15),remove
washer , filter(14)and clean.Re-assemble
in reverse order.
Water not hot enough - Water flow too high
- Heating setting too low
- Reduce water flow
- Turn knob to the right (max. position)
When selecting the temperature at
the draw off fitting, high water
temperatures may be reached. Children,
especially, should be kept from the fitting
due to the risk of scalding.
4. Warning