INSTALLATION
Preparation
ENGLISH
Oversink installation
D0000057030
12
1 Cold water inlet
2 DHW outlet
Note
Mount the appliance on the wall. The wall must have
sufficient load bearing capacity.
9.2 Minimum clearances
≥50≥50
≥90
≥90
D0000060809
Maintain the minimum clearances to ensure trouble-free op-
eration of the appliance and facilitate maintenance work.
9.3 Water installation
Flush the water line thoroughly.
Fittings
Use appropriate pressure taps. Open vented taps are not per-
missible.
Note
Never use the 3-way ball shut-off valve in the cold water
inlet to reduce the flow rate. The 3-way ball shut-off valve
is intended only to shut off the cold waterinlet.

Table of Contents

Other manuals for STIEBEL ELTRON DHE 18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON DHE 18 and is the answer not in the manual?

STIEBEL ELTRON DHE 18 Specifications

General IconGeneral
TypeInstantaneous Water Heater
Power Output18 kW
Voltage400 V
ControlElectronic
Protection ClassIP25
InstallationWall-mounted
Dimensions (H x W x D)478 x 225 x 105 mm
Phases3/PE
Frequency50/60 Hz
Specific water volume at Δt 30 K8.6 l/min
Specific water volume at Δt 35 K7.4 l/min
Specific water volume at Δt 25 K10.3 l/min
Energy efficiency classA
ApplicationDomestic