26 | DHM www.stiebel-eltron.com
INSTALLATION
Commissioning
!
Material losses
Take note of the type plate. The specified voltage must
match the mains voltage.
Connect the power cable as shown in the wiring diagram
(see chapter "Specification/ Wiring diagram").
5. Commissioning
5.1 Initial start-up
26�02�05�0087
Fill the appliance by running the tap several times until the
pipework and appliance are free of air.
Carry out a tightness check.
Insert the power cable plug, if present, into the standard
safety socket or set the fuse/MCB.
Check the function of the appliance.
5.2 Appliance handover
Explain the appliance function to users and familiarise them
with its operation.
Make users aware of potential dangers, especially the risk of
scalding.
Hand over these instructions.