INSTALLATION
Settings
www.stiebel-eltron.com LWZ 130 | LWZ 130 Enthalpie | 53
ENGLISH
12.1.4 "Settings" menu
Settings
Value
View Code for qualified con-
tractor
General
Time/date Day
Hour:Minute
Language
English
English
Francais
Nederlands
Italiano
Polski
Cesky
Magyar
Slovensko
中文
Slovensky
日本語
Contrast 1 - 10
Brightness %
Touch sensitivity 1 - 10
Touch boost
Prog. unit software
Fan control (depending on unit)
Constant flow rate
Constant pressure
Air flow rate
Flow rate, stage0 m³/h
Flow rate, stage1 m³/h
Flow rate, stage2 m³/h
Flow rate, stage3 m³/h
Supply air flow rate offset m³/h
Extract air diff. press. (depending on unit)
Diff. pressure, stage 0 Pa
Diff. pressure, stage 1 Pa
Diff. pressure, stage 2 Pa
Diff. pressure, stage 3 Pa
Favourites F1, F2, F3
F1
F2
F3
Bypass status
Extract air temp.
Extract air hum.
Filter runtime
Device software version
Device software patch
Mobile device serial no.
Humidity prot. Only for qualified con-
tractors
Enable humidity control (A2)
Off
On
Humidity prot. interval h
Humidity threshold %
Humidity capture delay min
Intens. vent.
Intens. vent. time min
Heat recovery bypass
Set room temperature °C
Operating mode heat recovery bypass
Disabled
Bypass/window contact
Outdoor air routing au-
tomatic
Extract air routing autom.
Temperature to enable heat recovery by-
pass
°C
Temperature to block heat recovery bypass °C
Hysteresis for heat recovery bypass K
Temp. differential for heat recovery bypass K
Window contact mode (A2)
(depending on unit)
Without window contact
With window contact
Cooling/heating, heat recovery bypass
Cooling/heating
Cooling
Heating
Frost protection Only for qualified con-
tractors
Frost protection temp. °C
Temp. to enable frost protection (A2) °C
Enable preheating Off
On
Frost protection mode
Outdoor air reg.
Supply air reg.
Passive house reg.
Condensate prevention (A2)
Enable condensate prevention
Off
On
Offset condensate prevention K
Enable fan Off
On
Ventilation unit
Device software version
Device software patch
Mobile device serial no.
Device type
Settings
View
Effect
Standard (A0)
The only parameters displayed are those that have been re-
leased for the appliance user and can therefore be accessed
without a code.
Service (A1) Parameters for qualified contractors: Code "1000"
Expert (A2) Parameters for service department.
f To access actual values and parameters which are reserved
for qualified contractors, enter the code "1000" for "View".
Press "OK".
"Service" is shown on the display, when this is entered correctly.
If you switch to the actual values or parameters, you see the en-
abled parameters.
Note
After entering the code, switch to the menu by pressing
the "MENU" button. If you first switch to the home screen,
the parameter block is reactivated.
Fan control (depending on unit)
Use this parameter to switch fan control between "Constant flow
rate" and "Constant pressure".
Effect
Constant flow
rate
The appliance maintains a constant flow rate for both fans.
The unit works with the set values set for "Flow rate, stage
0" to "Flow rate, stage 3".
Constant pres-
sure
The appliance maintains a constant pressure at the extract
air fan. The unit regulates the pressure at the extract air
connection to the set values set for "Diff. pressure, stage 0"
to "Diff. pressure, stage 3". The flow rate that is established
there is used as the set value for flow rate control of the
supply air fan. "Supply air flow rate offset" is also included.