24 | SHD www.stiebel-eltron.com
INSTALLATION
Maintenance
15.3 Replacing the protective anode
If the SERVICE ANODE indicator illuminates, check the signal
anode and replace if necessary. Spanner size for the anode
- SHD 30 S: SW 13
- SHD 100 S: SW 27
When replacing the anode, take great care to fit the pressure
switch on tightly (tighten by hand, torque value 100
+50
Ncm).
Observe the maximum permissible transition resistance 1.0Ω
between the anode and the cylinder
15.4 Descaling
Only descale the flange after disassembly.
Never treat the cylinder surface or the protective anode with
descaling agents.
15.5 Anti-corrosion protection
When carrying out service work, ensure that the anti-corrosion
protection on the insulating plate is not damaged or removed.
Reinsert the anti-corrosion protection correctly after replacement.
1
4
2
3
D0000048051
1 Anti-corrosion protection (390 Ω)
2 Pressure plate
3 Insulating plate
4 Flanged immersion heater