10. Commissioning
WARNING Electrocution
Commissioning may only be carried out by a qualified
contractor in accordance with safety regulations.
10.1 Initial start-up
1. 2.
D0000049325
f Either open the DHW valve of the tap or set the mono lever
mixer tap to "hot" until the water that flows out is free of air
bubbles.
f Insert the plug into the standard socket or set the fuse/MCB
in the fuse box.
f Select a temperature.
f Check the entire hydraulic installation for tightness.
Note
If you fail to follow the correct sequence (first water, then
power), the high limit safety cut-out will trip.
Proceed as follows:
f Disconnect the appliance from the power supply.
f Fill the appliance with water.
f Connect the appliance to the power supply.
10.1.1 Appliance handover
f Explain the functions of the appliance to the user. Show the
user how to operate the appliance.
f Make the user aware of potential dangers, especially the risk
of scalding.
f Hand over these instructions and, if applicable, the instruc-
tions for any accessories.
10.2 Recommissioning
See chapter "Installation/ Commissioning/ Initial start-up".
11. Settings
11.1 Setting the temperature limit
85
°C
35
55
65
Eco
c
om
f
o
r t
26�02�06�0007
1
2
1 Temperature selector
2 Limiting ring
Placing the limiting ring behind the temperature selector allows
you to limit the setting range of the temperature selector to a
specific maximum temperature.
f Turn the temperature selector to zero (fully anti-clockwise to
"°C").
f Pull off the temperature selector and the limiting ring.
f Push the limiting ring with the required maximum setting
onto the controller shaft.
f Install the temperature selector set to zero (°C).
12. Shutdown
f Isolate the appliance from the power supply by removing the
plug or by tripping the MCB in the fuse box.
f Drain the appliance (see chapter "Installation/ Maintenance/
Draining the appliance").
13. Troubleshooting
Problem Cause Remedy
The appliance does
not supply hot water.
The high limit safety
cut-out has responded.
Remedy the cause of the fault.
If necessary, replace the tem-
perature controller. Allow the
appliance to cool down. If you
have isolated the appliance from
the power supply, the high limit
safety cut-out will be reset au-
tomatically.
Loud boiling noises
inside the appliance.
The appliance is scaled
up.
Descale the appliance.