EasyManua.ls Logo

STIEBEL ELTRON SNU 5 SL - Appliance Installation and Connections; Mounting the Unit; Water and Electrical Connections

STIEBEL ELTRON SNU 5 SL
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.stiebel-eltron.com SNU 5 | 17
ENGLISH
INSTALLATION
Installation
9. Installation
9.1 Appliance installation
Mark out the drill holes using the installation template (see
middle part of these instructions).
Drill the holes and insert suitable rawl plugs.
Secure the wall mounting bracket using suitable screws.
Hang the appliance on the wall mounting bracket.
Note
Surplus cable can be stored in the cable compartment.
D0000034827
9.2 Water connection
!
Material losses
Carry out all water connection and installation work in
accordance with regulations.
!
Material losses
Counterhold with a suitable spanner when tightening the
fittings.
85
°C
35
55
65
Eco
c
om
f
or t
D0000034825
22
19
!
Material losses
The appliance may develop a leak and cease functioning.
Never subject the appliance to water pressure.
Never interchange the water connections.
Set the flow rate (see tap instructions). Observe the
maximum permissible flow rate with a fully opened
tap (see chapter "Installation/ Specification/ Data
table").
Match up the colour coding on the tap water connections and the
appliance:
- R. h. side blue = "Cold water inlet"
- L. h. side red = "DHW outlet"
Secure the water connections from the tap to the appliance.
Note
Ensure that the water connections are not kinked during
installation. Prevent any tensioning during installation.
9.3 Power supply
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at
least 3 mm contact separation.
!
Material losses
The voltage specified on the type plate must match the
mains voltage.
Observe the type plate.
The following electrical connections are permissible:
SNU 5 SL 1kW SNU 5 SLi
Connection to a freely accessible
standard socket
X X
Permanent connection to an ap-
pliance junction box with earth
conductor
X
X

Other manuals for STIEBEL ELTRON SNU 5 SL