EasyManua.ls Logo

STIEBEL ELTRON WWK 220 electronic - Assembling the Appliance

STIEBEL ELTRON WWK 220 electronic
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 | WWK 220-300 electronic www.stiebel-eltron.com
INSTALLATION
Installation
10.4.2 Connection with external signal transmitter
An external signal transmitter for switching a separate set DHW
temperature (set temperature2) can be connected to terminal
X0/2.
In the delivered condition, terminal X0/2 is not assigned. If this
terminal is connected to 230V, the appliance activates set tem-
perature2.
Following a one-off activation (signal is present for at least one
minute), set temperature2 applies for at least 20minutes and is
ranked higher than set temperature1.
WARNING Electrocution
If the 230V signal of an external signal transmitter is
to be connected to terminal X0/2, do not connect the
appliance to the power supply with the factory fitted
power cable and standard plug.
Instead connect the appliance to the power supply per-
manently. Never interchange L1 and N.
Note
Never wire up terminal X0/1.
Example 1: Power-OFF signal with own 230V phase
X0
1
2
L
L
N
N
PE
PE
L1
L1, L2 oder L3
N
PE
EVU:
D0000034589
Example 2: Photovoltaic signal via on-site relay and phase
routed outside the appliance
Note
The relay in the inverter must meet the following re-
quirements:
- Potential-free relay (240VAC / 24VDC, 1A) with
N/O contact
- Adherence to safety regulations and standards for
safety extra low voltage
- The switching output must be programmed so that
the relay closes or opens if certain limits are exceed-
ed or undershot (inverter output level).
If necessary, check with the inverter manufacturer wheth-
er the product meets the stated criteria.
X0
1
2
L
L
N
N
PE
PE
L1
N
PE
1
D0000034590
1 Inverter (floating contact)
The inverter power feed is located at a central distribution point
(e.g. in the main fuse box).
Connection to terminal block X0
Remove the appliance cover (see chapter "Cleaning and
maintenance/ Removing the appliance cover").
D0000034803
1
1 Terminal X0
Prepare the leads for connection to X0 in such a manner, that
each lead terminating at X0 has a wire ferrule.
Route leads through the strain relief.
Connect the leads to X0 (see chapter "Connection with exter-
nal signal transmitter").
10.5 Assembling the appliance
Note
Refit the appliance cover after completing your work. See
chapter "Maintenance and cleaning/ Fitting the appliance
cover").