OPERATION
Settings
ENGLISH
www.stiebel-eltron.com WWK 220-300 electronic | 9
In the set temperature1 menu, press the
menu key once to get to the menu for set
temperature2.
The "set temperature2" symbol appears.
The display of set temperature2 is denot-
ed with an "N".
Adjust set temperature2 to between 20
and 65°C using the plus and minus keys.
Operation with external signal transmitter (230 V input)
As standard, the appliances feature the ability to allocate a spe-
cific, individual set DHW temperature (set temperature2) to a
connected external signal transmitter, such as a PV system or a
low tariff transmitter.
This set temperature2 is activated when a phase (LF signal) is
present at terminal X0/2 (see chapter "Connection types"). While
activated, set temperature2 replaces the standard set DHW tem-
perature ("set temperature1").
If set temperature2 has been activated by the external signal
transmitter, this set temperature will then be active for at least
20minutes. If the signal remains active after those 20minutes
have passed, the compressor will run until the LF signal ends. If
not, the selected set temperature1 is activated again.
When the relevant set DHW temperature has been reached, the
compressor switches off and remains off for a minimum idle time
of 20minutes.
The following diagram illustrates the connections by means of a
sample signal sequence of an external signal transmitter.
Example:
- DHW temperature = 55°C
- Set temperature 1 = 50°C
- Set temperature 2 = 65°C
1
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 t [min]
B
1
1
0 2
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 t [min]
D0000034613
A LF signal
B Compressor
1 20 min. minimum runtime, set temperature 2
2 20 min. minimum compressor idle time
Note
An LF signal must be active for at least 60seconds, be-
fore the control unit responds to it. This will for example
prevent a brief burst of sunshine from triggering a heat-
up process, which due to a lack of further insolation can
then not be supplied with PV power generated on site.
4.3 Calling up fault codes
In the set temperature2 menu, press the
menu key once to get to the fault code
menu. A fault code will appear if a fault
has occurred. This menu remains inac-
tive if no fault has occurred.
See chapter "Troubleshooting/ Fault codes".
4.4 Rapid heating key
Press the rapid heating key.
The heat pump and electric emergency/
booster heater symbols appear.
4.4.1 Rapid/comfort heating
Normally, the rapid heating key is used to activate the rapid/com-
fort heating function, which enables you to cover an unexpect-
edly high DHW demand without changing any of the appliance's
standard settings.
If rapid/comfort heating is activated manually by pressing the rele-
vant key, the heat pump and the electric emergency/booster heater
will start in parallel, irrespective of the selected set temperature,
and will remain active until the DHW temperature in the cylinder
has reached 65°C. To save energy, the electric emergency/booster
heater switches off early, as soon as a temperature of 65°C has
been achieved in the upper cylinder section (rapid heating).
The rapid/comfort heating function remains active until a tem-
perature of 65°C has been achieved in the entire DHW cylinder
(comfort heating). The appliance then automatically switches back
to the previously set parameters.
Note
The electric emergency/booster heater and heat pump
symbols are displayed until the rapid/comfort heating
function has terminated.
During rapid/comfort heating, the electric emergency/
booster heater symbol is displayed until the heat pump
has heated the entire cylinder to 65°C and the function
is terminated. The electric emergency/booster heater al-
ready switches off when the 65°C has been achieved in
the upper cylinder section.
Note
If the rapid/comfort heating has been activated uninten-
tionally, you can cancel the function by lowering the set
temperature.
Hold down the minus key, until you hear a clicking
noise caused by the heat pump and emergency/
booster heater switching off. At the same time, the
set temperature also jumps back to the value that
was selected before rapid/comfort heating was ac-
tivated.
314104-38523-9034_WWK_220-300_electronic_en_pl.indb 9 24.02.2015 10:33:28