26 | WWK 220-300 electronic www.stiebel-eltron.com
INSTALLATION
Specication
15.1.3 WWK 300 electronic SOL
g02
g01
237
926
1252
1524
b01
d45
c06
c10
i43
h22
h23
c01
340
d34
750
d33
690
8-24
1913
D0000049127
WWK 300 electronic SOL
b01 Entry electrical cables
c01 Cold waterInlet Male thread G 1 A
c06 DHW outlet Male thread G 1 A
c10 DHW circulation Male thread G 1/2 A
d33 Heat source flow Female thread G 1
d34 Heat source return Female thread G 1
d45 Condensate drain Male thread G 3/4 A
g01 Air intake
g02 Air discharge
h22 Sensor heat source Diameter mm 9.6
h23 Sensor heat source optional Diameter mm 9.6
i43 Cover for manufacturing aperture