10
2.7 Specification
WWK 300 AH WWK 300 A
227070 222422
Power consumption
Power consumption at A15/W15-55 kW 0,5 0,5
Power consumption, emergency/booster heater kW 1,69
Coefficient of performance (COP)
Coefficient of performance at A15/W15-55 3,4 3,4
COPs to EN 255
Coefficient of performance to EN 255 3,19 3,19
Output data
Heating output at A15/W15-55 kW 1,7 1,7
Sound data
Sound pressure level at 1 m distance in a free field dB(A) 56 56
Sound power level (EN 12102) dB(A) 64 64
Application limits
Min. installation room floor area 6 6
Min. installation room volume 13 13
Hydraulic data
Rated capacity l 300 300
Energy data
Standby energy consumption/24 h at 65 °C kWh 1,14 1,14
Electrical details
Fuses A C 16 C 16
Rated voltage V 240 240
Phases 1/N/PE 1/N/PE
Frequency Hz 50 50
Rated current A 2,5 2,5
Power consumption W 2250 700
Max. power consumption W 2250 700
Versions
IP-Rating IP24 IP24
Refrigerant R134a R134a
Refrigerant capacity kg 0,9 0,9
Dimensions
Height of unit when tilted mm 1990 1990
Height when tilted incl. packaging mm 2200 2200
Height mm 1870 1870
Diameter mm 670 670
Weights
Weight (dry) kg 125 125
Connections
Condensate drain mm 20 20
Water connection G 1 (with adaptor Rp 3/4 female) G 1 (with adaptor Rp 3/4 female)
Values
Air flow rate m³/h 550 550
Lower air temperature limit °C 0 0
Upper air temperature limit °C 42 42
The output data refers to new appliances
with clean heat exchangers.