Troubleshooting
Before performing any work on the blower, remove the connecting cord plug from the machine's socket.
Condition Cause Remedy
Blower does not start when switched on
No electrical contact between connect-
ing cord and blower or battery
Disconnect cord between battery and
blower, inspect the cord and contacts,
reconnect the cord to the battery and
blower.
Battery has low charge
(1 LED on battery flashes green
1)
)
Charge the battery
Battery too hot / too cold
(1 LED on battery glows red)
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Fault in battery
(4 LEDs on battery flash red)
Disconnect and reconnect cord between
battery and blower. Switch on the blower
– if the LEDs continue to flash, the bat-
tery has a malfunction and must be
replaced.
Blower is too hot
(3 LEDs on battery glow red)
Blower is too hot – allow it to cool down.
Electromagnetic problem or fault in the
blower
(3 LEDs on battery flash red)
Disconnect and reconnect cord between
battery and blower. Switch on the blower
– if the LEDs still flash, the blower has a
malfunction and must be checked by a
servicing dealer
3)
.
Moisture in blower and/or battery Allow blower / battery to dry