23 Troubleshooting Guide
3 LEDs flash
red.
Malfunction in
blower.
Remove and reinsert the connecting cord, @ 14.
Switch on the blower, @ 15.1.
If the LEDs still flash, do not attempt to use.
The blower has a malfunction and must be checked by a
servicing dealer.
Blower cuts out
during operation.
1 LED glows
red.
Battery too hot / too
cold.
Remove the connecting cord, @ 14.2.
Allow the blower and battery to cool down gradually at
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
3 LEDs glow
red.
Blower too hot.
Run-time is too short. Battery not fully
charged.
Charge the battery as described in its instruction manual.
Useful life of battery
has been reached or
exceeded.
Have the battery checked by an authorized STIHL servicing
dealer.
Always remove the connecting cord before carrying out any inspection, cleaning or maintenance.
Condition LEDs on
Battery
Cause Remedy