Troubleshooting
Always remove the battery before carrying out any work on the power tool.
Condition Cause Remedy
Machine does not start when switched on
No electrical contact between power tool
and battery
Remove the battery, visually check con-
tacts and refit battery
Battery has low charge
(1 LED on battery flashes green)
Charge the battery
Battery too hot / too cold
(1 LED on battery glows red)
Allow battery to cool down / allow battery
to warm up slowly at temperature of
about 15°C - 20°C
Fault in battery
(4 LEDs on battery flash red)
Take the battery out of the power tool
and refit it. Switch on the machine if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Power tool too hot
(3 LEDs on battery glow red)
Allow power tool to cool down
Electromagnetic problem or fault in
machine
(3 LEDs on battery flash red)
Take the battery out of the power tool
and refit it. Switch on the power tool – if
the LEDs still flash, the power tool has a
malfunction and must be checked by a
servicing dealer
1)
.
Moisture in power tool and/or battery Allow power tool / battery to dry
Machine cuts out during operation
Battery or machine's electronics too hot Take battery out of machine, allow bat-
tery and machine to cool down
Electrical or electromagnetic malfunction Remove the battery and refit it
Running time is too short
Battery not fully charged Charge the battery
Using unsuitable nylon line Replace nylon line
Useful life of battery has been reached
or exceeded
Check battery
1)
and replace
Battery jams when being inserted in power
tool / charger
Guides / contacts dirty Carefully clean the guides / contacts

Table of Contents