HSA 65, HSA 85
English
48
Troubleshooting
Always remove the battery before carrying out any work on the power tool.
Condition Cause Remedy
Machine does not run when switched on
No electrical contact between power tool
and battery
Remove the battery and refit it properly
Battery discharged
(1 light emitting diode on battery flashes
green)
Charge the battery
Battery too hot / too cold
(1 light emitting diode on battery lights
up red)
Allow battery to cool down / warm up
Battery faulty
(4 light emitting diodes on battery flash
red)
Install new battery
1)
Power tool too warm
(3 light emitting diodes on battery light
up red)
Allow power tool to cool down
Power tool faulty
(3 light emitting diodes on battery flash
red)
Have checked by servicing dealer
1)
Moisture in power tool and/or battery Allow power tool/battery to dry
Power tool cuts out during operation
Battery or power tool circuitry too warm Take the battery out of the power tool;
allow the battery and power tool to cool
down
Electrical malfunction Remove the battery and refit it properly