HTA 65, HTA 85
English
26
During Operation
The green LEDs glow continuously or
flash to indicate the state of charge.
If the LEDs on the battery flash or glow
red – see "If the red LEDs glow
continuously / flash".
If the red LEDs glow continuously / flash
3901BA016 KN
80 - 100 %
60 - 80 %
40 - 60 %
20 - 40 %
0 - 20 %
A 1 LED glows
continuously
red:
Battery is too
hot
1) 2)
/cold
1)
1)
When charging: Charge process
starts automatically after the battery
has cooled down / warmed up.
2)
During operation: Power tool cuts
out – allow battery to cool down; it
may be necessary to take the
battery out of the power tool for this
purpose.
B 4 LEDs flash
red
Malfunction in
battery
3)
C 3 LEDs glow
continuously
red:
Power tool is too
hot – allow it to
cool down.
D 3 LEDs flash
red
Malfunction in
power tool
4)
3901BA041 KN
A
B
C
D
3)
Electromagnetic interference or
fault. Take the battery out of the
power tool and refit it. Switch on the
machine – if the LEDs continue to
flash, the battery has a malfunction
and must be replaced.
4)
Electromagnetic interference or
fault. Take the battery out of the
machine. Use a blunt tool to
remove dirt from the contacts in the
battery compartment. Refit the
battery. Switch on the power tool –
if the light emitting diodes still flash,
the power tool is faulty and must be
checked by a servicing dealer –
STIHL recommends an authorized
STIHL servicing dealer.