FS 460 C-M, FS 460 C-M L
English
39
Maintenance and Care
The following intervals apply to normal operating conditions only. If your daily work-
ing time is longer or operating conditions are difficult (very dusty work area, etc.),
shorten the specified intervals accordingly.
before starting work
after finishing work or daily
after each refueling stop
weekly
monthly
every 12 months
if problem
if damaged
if required
Complete machine
Visual inspection (condition, leaks) XX
Clean X
Control handle Check operation XX
Air filter
Clean XX
Replace X
Pickup body in fuel tank
Check
1)
X
Replace
1)
XXX
Fuel tank Clean XXX
Engine idle speed
Check – the cutting attachment must not
turn
XX
If the cutting attachment turns when the
engine is idling, have machine repaired
by servicing dealer
1)
X
Spark plug
Readjust electrode gap X
Replace after every 100 operating hours
Cooling inlets
Visual inspection X
Clean X
Spark Arrestor in Muffler
Check
1)
XX
Clean or replace
1)
X
Combustion chamber
Decoke after first 139 hours of opera-
tion, then every 150 hours of operation
X
All accessible screws and nuts (not adjust-
ing screws)
Retighten X
Antivibration elements
Check XXX
Replace
1)
X

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stihl Operating instructions and is the answer not in the manual?

Stihl Operating instructions Specifications

General IconGeneral
BrandStihl
ModelOperating instructions
CategoryTrimmer
LanguageEnglish

Related product manuals