RE 143, RE 143 PLUS, RE 163, RE 163 PLUS
English
18
After use
N Roll the high-pressure hose and 
power cable up on the brackets 
provided for this purpose – see 
"Main Parts"
N Unplug the power plug from the 
socket
N Disconnect hose from the water 
supply and from the machine
N Rolling up the high-pressure hose 
and storing the spray attachment
Store the machine in a dry room where it 
is protected from frost.
If protection from frost cannot be 
guaranteed, draw glycol-based 
antifreeze – like that used in motor 
vehicles – into the pump:
N Insert water intake hose in container 
with antifreeze
N Insert spray gun without spray lance 
in the same container
N Switch on the machine with the 
spray gun open
N Actuate the spray gun until a 
uniform jet emerges 
N Keep leftover antifreeze in a sealed 
container
After Finishing Work
1607BA065 ST
Storing the Machine