RE 143, RE 143 PLUS, RE 163, RE 163 PLUS
English
23
Electrical specifications 
RE 143, RE 143 PLUS
RE 163, RE 163 PLUS
Hydraulic specifications
RE 143, RE 143 PLUS
RE 163, RE 163 PLUS
Specifications
Power supply: 230 V / 1~ / 50 Hz 
1), 4)
220 V / 1~ / 50 Hz 
2)
220 V / 1~ / 60 Hz 
3)
Power output: 2.9 kW
 1) 3)
2.2 kW 
2)
2.8 kW 
4)
Ampere rating: 12.6 A 
1)
10 A 
2)
13.2 A 
3)
12.2 A 
4)
Fuse, slow 
(characteristic 
"C" or "K"):
13 A 
1) 2) 4)
15 A 
3)
Protection 
class: I
Type of 
protection: IP X5
1)
230 V / 50 Hz version
2)
220 V / 50 Hz version
3)
220 V / 60 Hz version
4)
230 V / 50 Hz version GB
Power supply: 230 V / 1~ / 50 Hz
230 V - 240 V / 
1~ / 50 Hz 
5)
Power output: 3.3 kW
2.4 kW 
5)
Ampere rating: 14.3 A
10 A 
5)
Fuse, slow (char-
acteristic "C" or 
"K"):
16 A
10 A 
5)
Protection class: I
Type of 
protection: IP X5
5)
230 V - 240 V / 50 Hz version
Working pressure: 14 MPa 
1)
 
(140 bar)
12 MPa 
2)
 
(120 bar)
12.2 MPa 
3)
 
(122 bar)
12.8 MPa 
4)
 
(128 bar)
Max. permissible 
pressure:
15 MPa 
(150 bar)
Max. water feed 
pressure:
1MPa 
(10 bar)
Max. water throughput: 610 l/h 
1) 4)
520 l/h 
2)
700 l/h 
3)
Water throughput as per 
EN 60335-2-79:
540 l/h 
1)
470 l/h 
2)
660 l/h 
3)
570 l/h 
4)
Max. suction lift: 0.5 m
Max. water feed temperature
With pressurized water 
supply: 60 °C
Suction operation: 20 °C
Max. kickback force: 25.1 N 
1)
20.2 N 
2)
28.6 N 
3)
25.3 N 
4)
1)
230 V / 50 Hz version
2)
220 V / 50 Hz version
3)
220 V / 60 Hz version
4)
230V/50Hz version GB
Working pressure: 15 MPa 
(150 bar)
12 MPa 
5)
 
(120 bar)
Max. permissible 
pressure:
16 MPa 
(160 bar)
Max. water feed 
pressure:
1MPa 
(10 bar)
Max. water throughput: 650 l/h
520 l/h 
5)
Water throughput as per 
EN 60335-2-79:
570 l/h
470 l/h 
5)
Max. suction lift: 0.5 m
Max. water feed temperature
With pressurized water 
supply: 60 °C
Suction operation: 20 °C
Max. kickback force: 27.4 N
20.2 N 
5)
5)
230 V - 240 V / 50 Hz version